Abus-technologies DP Series Smart Pressure Transmitter Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 15
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
ABUS TECHNOLOGIES INC.
M94
7
Mounting Orientation Effect: Zero drifts no more than 0.24kPa. No effect for movement
parallel to diaphragm. The error could be resolved by quick Zero
reset pushbutton on the instrument.
Power Voltage: 12V ~ 45V DC
Intrinsically safe/explosion-proof products with max 30 VDC
should be powered by safe Barrier
Parameters for intrinsically safety: U
0
28V DC,
type outsourcing safe barrier I
0
30mA
P
0
0.84W
Physical Parameters:
O Ring of Contacting Medium: Viton / Glass Filled PTFE
Filling liquid: Silicone Oil / Inert Gas
Bolt: Cadmium plated carbon steel.
Outer shell or electronic circuit: Low Cu Al.
O shaped seal ring: Acrylotrile-butadiene rubber, fluorine rubber polyurethane.
NOTE: Please refer to Ordering Table for Flange connector, Exhaust/Vent valves and Isolation
Diaphragm Material options
Pressure Connection Part: ¼ - 18 NPT for joint thread in pressure room,
½ - 14 NPT for joint thread in pressure guiding joint.
Weight: Basic Model, 2.4Kg
Operation Environment under Normal Conditions
Operation Temperature(Ambient): Smart Type:-20°C ~ +85°C.
Storage Temperature: -40°C ~ +104°C
Humidity: 0 ~ 90%
Atmospheric Pressure: 86 ~ 106 kPa
Operation Environment Conditions for Explosion-Proof Product
Humidity: -20°C ~ +40°C
Relative Humidity: 5% ~ 95%
Atmospheric Pressure: 86 ~ -106 kPa