5. CONNECTIONS
The transmitter can be ordered as 4-20 mA current output or 0 to 10 Vdc
voltage output. The output signal is defined on purchase and cannot be later changed.
Variables can be monitored together or separately. Combinations of mobile jumpers
J4 and J5 within the transmitter case define how variables will be used. The jumpers
also define the transmitter terminals with available output signals.
J4 and J5 position within the transmitter
Figures below shows the required electrical connections:
LOAD represents the output signal measurement equipment (controller, register, etc).
The connection wires go inside the transmitter through to the cable gland mounted in
the transmitter case.
Jumper J5 Jumper J4 OUT1 OUT2
Position A Position A Temperature Humidity
Position A Position B Temperature Off
Position B Position A Humidity Off
Position B Position B Humidity Temperature
4-20 mA connections 0-10 VDC connections
4-20 mA connections with single source
04-20 mA model with single source and load with
two input channels